Models
[Thermometer]
- Radiation thermometer for low temperature
Types |
Distance factors |
Models |
| Standard |
50 |
IR-AL0CB |
| For small diameter
with short distance |
2/100mm
|
IR-AL8CB-1
|
4/200mm
|
IR-AL8CB-2
|
- Radiation thermometer for medium/high temperature
Distance factors |
Detectors |
PbSe |
PbS |
Ge |
Si |
50 |
-- |
-- |
IR-AP0CG |
IR-AP0CS |
100 |
IR-AP1CE |
IR-AP1CP |
IR-AP1CG |
IR-AP1CS |
200 |
-- |
-- |
-- |
IR-AP2CS |
300 |
-- |
IR-AP3CP |
IR-AP3CG |
IR-AP3CS |
Distance factors |
Detectors |
Ge |
Si |
35 |
IR-AQ8CG |
-- |
50 |
IR-AQ0CG |
-- |
100 |
IR-AQ1CG |
IR-AQ1CS |
200 |
-- |
IR-AQ2CS |
300 |
-- |
IR-AQ3CS |
[Converter]
Types |
Models |
| Panel-back-mount type |
IR-GAB |
| Panel mount type |
IR-GAP |
| Wall mount type |
IR-GAW |
| Panel mount type with
multi-function |
IR-GAG |
Specifications
[Thermometer]
Items |
For low
temperature
IR-AL |
For
medium/high temperature
IR-AP |
|
Measuring
systems |
Wide
band radiation thermometer |
Narrow
band radiation thermometer |
2-color
thermometer |
Temperature
ranges |
-50
to 1000 |
400
to 1300 and other ranges in 100 to 3500
|
800
to 1800 and other ranges in 400 to 3100
|
Detectors
|
Pyroelectric
|
PbSe,
PbS, Ge, Si |
Ge,
Si |
Spectral
ranges |
8
to 13 m |
PbSe:
4 m
PbS: 2 m
Ge: 1.6 m
Si: 0.96 m |
Ge:
1.5/1.65 m
Si: 0.8/0.97 m |
Accuracy
ratings |
Less
than 200 : 2
More than 200 : 2% of reading |
PbSe,
PbS, Ge:
Less than 500 : 3
500 to 1000 : 5
More than 1000 : 0.5% of reading
Si:
Less than 1500 : 0.5% of reading
1500 to 2000 : 1% of reading
More than 2000 : 2% of reading |
400
to 700 : 1% of reading
700 to 1500 : 0.5% of reading
1500 to 2000 : 1% of reading
More than 2000 : 2% of reading |
Resolutions
|
1 (for the measured temperature more than 50 )
|
Ge,
Si: 1.5 (less than 400 ), 1 (more than 400 )
PbSe, PbS: 2 (less than 300 ), 1 (more than 300 ) |
2 |
Repeatability
|
Within
1 |
Response
time |
0.5
second (95% response)
(on output of converter) |
0.2
second (95% response)
(on output of converter) |
0.3
second (95% response)
(on output of converter) |
Distance
factors |
50
|
50,
100, 200, 300 |
35,
50, 100, 200, 300 |
Measuring
distance |
0.5
m to |
Measuring
diameter |
Measuring
distance/Distance factor |
Collimation
|
Direct
viewfinder |
Operating
temperature |
0
to 50
0 to 150 (on water-cooling by water cooling jacket) |
Connection
|
Terminal
connection or connector connection |
Connection
cable length |
Up
to 200m by exclusive cable |
Weight
|
About
1.9kg |
[Converter]
Display |
Panel-back-mount
type
IR-GAB |
Panel mount
type
Wall mount type
IR-GAP, IR-GAW |
Panel mount type with multi-function
IR-GAG |
Emissivity
(Emissivity ratio) |
0.100 to 1.000 (0.800 to 1.200) |
Modulator
|
Delay:
Trace of average value (smoothing) |
Real: Original signal
Peak: Trace of maximum value
Delay: Trace of average value (smoothing)
Valley: Trace of minimum value |
Display
|
--
|
LED 4 digits (red) |
Output
signal |
4
to 20mADC (Load resistance: less than 550 )
0 to 10mVDC (Output resistance 10 )
Isolate output |
4 to
20mADC (Load resistance: less than 550 )
0 to 10mVDC (Output resistance 10 )
Independent isolate output |
Output
scaling |
By
standard range |
Zero and span are freely adjustable 1 step. |
Output
renewal cycle |
0.1 second |
Alarm
output |
--
|
High/low independent setting
Output terminals: 2 sets of H, C, and L terminals
Contact capacity: 100VAC, 1A (resistive load) |
Power
supply |
100, 110, 200 or 220VAC (to be specified), 50/60Hz |
Power
consumption |
Maximum 30VA |
Maximum
40VA |
Operating
temperature range |
0 to 50 |
Calculation
|
--
|
--
|
Block processing, reflection
correction, emissivity (ratio) program, 2-input selection, emissivity calibration |
Weight
|
About
2kg |
Panel
mount type:
About 2.5kg
Wall mount type:
About 6kg |
About
4kg |
Option
|
--
|
--
|
RS-232C
or RS-422A
(to be specified) |
|